Setup
4-12
Part 1123087_02
3/2014 Nordson Corporation
Control System Setup Procedures
Refer to About the Control System earlier in this section for an overview of
the control system and a diagram of the control system screen hierarchy.
Refer to About Heated Components earlier in this section for an explanation
of heated zones.
Modifying Temperature Setpoints for Individual Zones
Follow this procedure to enter a specific temperature setpoint for a heated
zone. To enter the same temperature setpoint for all heated zones, refer to
Entering or Modifying a Global Temperature Setpoint later in this section.
1.. From the Home screen, touch Grid, Manifold, an applicator zone button
(Zone 1B, Zone 2B, Zone 3B, or Zone 4B), or a hose zone button
(Zone1A, Zone 2A, Zone 3A, or Zone 4A).
2.. Touch Adjust Setpoint and use the keypad to enter the desired value for
the selected zone. Refer to Table 4‐2 for an explanation of this parameter
and the default and optional settings.
3.. Touch Done.
Grid
175C
Manifold
175C
Zone 1B
175C
Zone 2B
175C
Zone 3B
175C
Zone 4B
175C
Zone 1A
175C
Zone 2A
175C
Zone 3A
175C
Zone 4A
175C
Master
Controls
Pump: On
Heaters: On
Password: Disabled
Recipes:
Nothing Loaded
Fill Status
Pump
On
System Status:
Ready/OK
175C
Zone 4B
175C
175C
Zone 2A
175C
175C
Zone 4A
175C
Recipes:
Nothing Loaded
System Status:
Ready/OK
Create/Modify NameAdjust Setpoint
Zone State: Enabled
Done
Zone 1B
Zone 1B
EcoBead Settings
175C
Ready
Figure 4‐5 Accessing an external zone screen (Zone 1B screen shown)