Loading...
Pump air pressure adjustment
screw (requires a 5‐mm hex
wrench)
Installation
3-36
Part 1123087_02
3/2014 Nordson Corporation
Connect an Air Supply to the Melter
To achieve maximum adhesive output, the system must be connected to an
air supply that is capable of providing a maximum of 6.2 bar (90 psi) of dry,
non‐lubricated air.
CAUTION! Risk of equipment damage. Do not force the pump air pressure
adjustment screw beyond its normal range of adjustment. Doing so will
damage the pneumatic assembly.
See Figure 3‐26.
1. Use a 5‐mm hex wrench to turn the pump air pressure adjustment
screw(1) counterclockwise until it stops (off).
2. Insert the male fitting on the outlet side of the air filter assembly(3)
(P/N1121428 from the ship‐with kit) into the air inlet port (2) on the
melter.
CAUTION! Risk of equipment damage. Connecting a heavy air supply line to
the air filter can damage the equipment.
3. Rigidly support the plant air supply line and connect it to the air filter
assembly inlet. Refer to Table 3‐4 to determine the fitting required based
on the type of air supply line being connected.
Table 3‐4 Air Supply Filter Inlet Fitting Requirements
Air Supply Line Connection Procedure
8‐mm (
5
/
16
in.) plastic
tubing
Connect the air supply tubing to the air filter
assembly inlet. No additional fittings are
required.
G1/4 (
1
/
4
BSPP) pipe
thread
Remove the existing 8‐mm (
5
/
16
‐in.) fitting and
install a customer‐supplied G¼ fitting in the air
filter inlet.
1
/
4
NPT pipe thread Remove the existing 8‐mm (
5
/
16
‐in.) fitting and
install the ¼NPT‐to‐G¼ BSPP male adapter
fitting (P/N 1034145) from the ship‐with kit in
the air filter inlet.