Technical Data
10-2
Part 1123087_02
3/2014 Nordson Corporation
Heater Specifications
NOTE: Refer to the hose and applicator manuals for hose/applicator heater
specifications.
Location Voltage
Wattage
(see Note A)
Approximate
Cold Resistance
(see Note B)
Grid/hopper 230 V 1600 30-35 ohms
Reservoir 230 V 900 53-62 ohms
NOTE A: Nominal wattage at 177−204 C (350−400 F).
B: Measured at room temperature for a previously heated element.
Pump Specifications
Item Data
Air pressure while running 70-689 kPa (10-100 psi)
Minimum air pressure 0.7 bar (10 psi)
Viscosity range 800-10,000 cps
Pressure ratio 15:1
Air consumption at 415 kPa (60 psi) and maximum pump speed 46 l/min. (1.6 scfm)
Displacement 7.20 ml/stroke ( 0.44 in
3
/stroke)
Maximum speed 90 strokes/min.