Operation
5-14
Part 1123087_02
3/2014 Nordson Corporation
Pump Status
The pump button provides state and status information for the zone, as
shown in Figure 5‐7.
Refer to Table 5‐6 for an explanation of all pump button state and status
indications.
Pump
Pump status
Purge
On
Pump state
Auto Pump selection
(in this case, Auto
Pump is Off)
Figure 5‐7 Pump button indications
Table 5‐6 Pump Button State and Status Indications
Pump States
Button Color State Indication
Pump
On
Dark green On The system status is Ready/OK and the pump is On.
NOTE: When the pump is On, it attempts to pump even if
the system status is not Ready/OK. Nordson Corporation
recommends not starting the pump until the system status
is Ready/OK.
Auto Pump
On
Dark green On The pump is On because it was automatically switched on
when the melter reached Ready/OK status.
NOTE: The second line (On) indicates whether the pump
is pumping (On) or not pumping (Disabled). It does not
indicate whether the Auto Pump setting is On or Off. If the
first line is Auto Pump, as in this example, then Auto Pump
is On. If the first line is Pump, then Auto Pump is Off.
Disabled
Pump
White Disabled The pump is switched Off.
Disabled
Pump
Remote IO
White Disabled The pump was switched Off by a remote input.
Continued...