Operation
5-13
Part 1123087_02
3/2014 Nordson Corporation
Table 5‐5 Heated Zone Button State and Status Indications
Zone States
Button Color State Indication
EcoBead
White Disabled At least one applicator is connected to the system.
Gray Unavailable No applicators are connected to the system.
Zone Status
Button Color Status Indication
Zon
e 1A
Set Point
176C
145_
C
Zone 1A
145 C
Dark green Ready/OK The zone is enabled and has reached its setpoint
temperature.
Zone 1A
145_C
Zone 1A
145 C
Light green Waiting for
Ready
The zone is enabled and is in the process of heating to
its setpoint temperature.
The system is in either the Standby or Ready Delay
mode.
The zone is in an alert or fault condition.
The system is in an alert or fault condition.
Zone 1A
Alert
Yellow Alert The zone is enabled, but the system has detected an alert
condition.
NOTE: When an alert occurs, Heater Control and Pump
Control remain On. You have two minutes from the time
the system detects an RTD or an overtemperature/
undertemperature condition until the alert changes to a
fault.
Zone 1A
Fault
Red Fault The zone is enabled, but the system has detected a fault
condition.
NOTE: When a fault occurs, Heater Control and Pump
Control are switched Off.