Installation
3-43
Part 1123087_02
3/2014 Nordson Corporation
Remove the Shipping Bolt
1. Remove the hydraulics cover. Refer to Removing or Installing Covers in
Section6, Maintenance, as needed.
2. See Figure 3‐29. Remove and discard the M5 shipping bolt that secures
the hydraulic assembly to the melter chassis. The bolt was required for
shipping purposes only.
NOTE: Do not reinstall the hydraulics cover. It needs to stay removed for
the fill system installation procedures.
Figure 3‐29 Removing the shipping bolt