Setup
4-4
Part 1123087_02
3/2014 Nordson Corporation
Home Screen
The Home screen is used to:
Enable/disable zones, enter individual zone temperature setpoints,
and create/modify zone names
Start/stop the pump, change the Auto Pump setting, and purge the
melter
View the System Status (refer to Table 5‐3 in Section 5, Operation, for
a list of all System Status button indications)
View the following: Fill Status, Pump state and status, heated zone
states and statuses, Password protection status, and recipe use
Access the Master Controls screen
Grid
175C
Manifold
175C
Zone 1B
175C
Zone 2B
175C
Zone 3B
175C
Zone 4B
175C
Zone 1A
175C
Zone 2A
175C
Zone 3A
175C
Zone 4A
175C
Master
Controls
Pump: On
Heaters: On
Password: Disabled
Recipes:
Nothing Loaded
Fill Status
Pump
On
System Status:
Ready/OK
Internal
heated
zone
buttons
Fill Status and
Pump control
buttons
Recipe button
and status
indication
System
Inventory
button
Pump, heaters,
and password
status indications
System Status
indication
Master Controls
button used to
access the
System and
Settings buttons
Applicator
heated
zone
buttons
Applicator
heated zone
buttons
Hose heated
zone buttons
Hose heated
zone buttons
System Data
button
Ready
Figure 4-1 Home screen buttons and indications