Table 5‐3 System Status Button/Screen Saver Indications
Button Color Heaters Pump Description
System Status
Ready/OK
Dark
green
On On All enabled heated zones are at
setpoint temperature and the fill
system is ready.
System Status
Ready/Service
Dark
green
On On Same as Ready/OK, but a component
requires regularly scheduled service.
System Status
Heaters Off
System Status
Heating Fill: Ready
Light
green
On Off The system is heating all enabled
zones to their setpoint temperatures.
Refill is enabled.
System Status
Heaters Off
System Status
Heat: Ready Fill: Off
Light
green
On Off Heated zones are at setpoint
temperature, but Refill is disabled.
System Status
Heat: Off Fill: Ready
Light
green
Off Off Heated zones are at setpoint
temperature and the pump is ready,
but Heater Control is Off.
NOTE: This could be the result of a
heated zone fault.
System Status
Heaters Off
System Status
Heat: Off Fill: Off
Light
green
Off Off Heated zones are at setpoint
temperature, but Heater Control is Off
and Refill is disabled.
System Status
Heating Fill Off
Light
green
On Off The system is heating all enabled
zones to their setpoint temperatures.
System Status
Ready Delay
Light
blue
On Off Although all heated zones are at
setpoint temperature, Ready/OK status
is delayed until the Ready Delay time
has elapsed.
System Status
Standby Mode
Blue On Off The system has been manually or
automatically placed into Standby
mode.
System Status
Alert
Yellow On On The melter continues to operate
normally, but some functions may not
be available. The system requires
service.
System Status
Fault
Red Off Off A system fault condition has been
detected. Pump Control and Heater
Control are switched Off.