Contents of main board fuse
service kit:
F1 and F2
(Fast, 10 A, 250 VAC)
F3 and F4
(Slow, 2 A, 250 VAC)
F5 and F6
(Fast, 5 A, 250 VAC)
F7–F10 (2 spares provided)
(6.3 A, 250 VAC)
Repair
8-20
Part 1123087_02
3/2014 Nordson Corporation
Replacing the Main Board Fuses
You will need the following items:
Main board fuses service kit
5‐mm hex key
Fuse puller
Refer to Section 9, Parts, for service kit part numbers.
1. Switch off the melter and disconnect and lock out input power to the
melter.
2. Remove the controls cover. Refer to Removing or Installing Covers in
Section 6, Maintenance, as needed.
See Figure 8‐12.
3. Remove the fuse cover, and then use a fuse‐puller to remove and replace
the desired fuse(s). Reinstall all fuse covers when finished.
4. Reinstall the controls cover and restore the system to normal operation.
F1/F2 Grid heater
F3/F4 Main power to board
F5/F6 Manifold heater
F7/F8 Hose/applicator 1 heaters
F9/F10 Hose/applicator 2 heaters
Fuse Key
Figure 8‐12 Location of the main board fuses