Loading...
Fill
Settings
Master
Controls
Troubleshooting
7-29
Part 1123087_02
 3/2014 Nordson Corporation
Using Manual Call for Fill
For some testing or troubleshooting actions, you may need to manually
activate the fill system.
CAUTION! Risk of equipment damage. Manually activating the fill system
overrides normal operation and can result in an overfill situation, which can
cause adhesive to enter the exhaust section of the melter.
1. From the Home screen, touch Master Controls > Settings > Fill >
Manual Call for Fill.
2. If you are sure you want to activate the fill system, touch Activate.
The system activates the fill system, transferring adhesive for
approximately 2 seconds per button touch.
Fill Level Graph
Alert to Fault Delay Time
Overfill Delay
Done
Fill Flutter Delay
Fill Settings
Manual Call for FillFill Calibration
Home
Audible Fill Alarm
60 sec.
Enabled
5 sec.
4 min.
Warning! Use of the Manual Call to Fill function overrides normal operation and can
result in an overfill situation with adhesive entering the exhaust section of the melter.
Never operate system with filter or filter cover removed.
Attention
Activate Cancel
Figure 7‐14 Manually activating the fill system