Contents of the level sensor cable
service kit:
Level sensor cable
Repair
8-10
Part 1123087_02
3/2014 Nordson Corporation
Replacing the Level Sensor Cable
You will need the following items:
Level sensor cable service kit
3‐mm and 5‐mm hex keys
8‐mm open‐end wrench
Refer to Section 9, Parts, for service kit part numbers.
To prepare for this procedure
1. Switch off the melter and disconnect and lock out input power to the
melter.
2. Remove the controls and hydraulics covers. Refer to Removing or
Installing Covers in Section 6, Maintenance, as needed.
3. Open the insulation around the hydraulics assembly.
4. See Figure 8‐6. Pull the spring-loaded pin and carefully tilt open the
hydraulics assembly.
Figure 8‐6 Location of the spring‐loaded pin used to tilt open the hydraulics
assembly