Setup
4-20
Part 1123087_02
3/2014 Nordson Corporation
Selecting the Auto Pump Setting
Follow this procedure to specify whether the pump starts automatically after
all zones have reached setpoint temperature.
1.. From the Home screen, touch Pump.
2.. Touch Auto Pump to switch the setting to On or Off. Refer to Table 4‐5
for an explanation of this parameter and the default and optional setting.
NOTE: When Auto Pump is On, the pump button indicates Auto Pump.
Refer to Pump Status in Section 5, Operation, for more information on the
pump button indications.
3.. Touch Done.
Grid
175C
Manifold
175C
Zone 1B
175C
Zone 2B
175C
Zone 3B
175C
Zone 4B
175C
Zone 1A
175C
Zone 2A
175C
Zone 3A
175C
Zone 4A
175C
Master
Controls
Pump: On
Heaters: On
Password: Disabled
Recipes:
Nothing Loaded
Fill Status
Pump
On
System Status:
Ready/OK
Recipes:
Nothing Loaded
System Status:
Ready/OK
Purge
Auto Pump
OffPump: On
Done
Pump Control
Pump
Off
Ready
Figure 4‐10 Pump screen
Table 4‐5 Auto Pump Default Setting
Button Description Default Setting Optional Setting
Auto Pump Switches On or Off the automatic
pump startup function. If Auto Pump
is On, the pump automatically starts
when all zones reach their setpoint
temperatures.
Off On