EasyManua.ls Logo

Nordson freedom - Mounting the Melter on the Floor Stand

Nordson freedom
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
3-10
Part 1123087_02
3/2014 Nordson Corporation
Mounting the Melter on the Floor Stand
The melter floor stand can be:
Bolted to the floor (no base plate or casters)
Free standing, using the optional base plate kit
Free standing, using the optional casters kit
NOTE: The floor stand and the optional base plate and casters kits are
ordered separately. Refer to Optional Accessories in Section 9, Parts, for
part numbers.
1. Perform whichever of the following steps is applicable for your
installation:
To bolt the stand to the floor—drill and tap holes as shown in
Figure 3‐8 for four customer‐supplied bolts and secure the floor stand
to the mounting surface.
To install the optional base plate—install the base plate from the
base plate kit on the floor stand base using the hardware from the kit.
To install the optional casters kit—install the base plate from the
casters kit on the floor stand base using the hardware from the kit (the
casters are preinstalled); lock the casters to prevent movement
during the next steps.
51
2.00
267
10.50
279
11.00
51
2.00
279
11.00
156
6.13
4X
9.53
.375
57
2.25
MELTER MOUNTING BRACKET TO
BE INSTALLED ON THIS SURFACE
HOLES FOR 5/16‐IN. OR M8 SCREWS
Figure 3‐8 Melter floor stand mounting hole pattern in [mm] in.
Note: In the next step, the melter mounting bracket is installed at the location shown in Figure 3‐8.