Control System Settings
B-1
Part 1123087_02
3/2014 Nordson Corporation
Appendix B
Control System Settings
The following tables provide the factory defaults and optional settings (if
applicable) for all editable settings.
Home Screen
Home Screen
Button/Menu Item Default
Range of Values or
Optional Settings
Grid Adjust Setpoint 175 C (350 F) 40-204 C (100-400 F)
Manifold Adjust Setpoint 175 C (350 F) 40-204 C (100-400 F)
Fill Fill Enabled Disabled
Pump
Pump Control Off On
Purge Off On
Auto Pump Off On
Zone 1B, Zone 2B,
Zone 3B, or Zone 4B
Zone 1B, Zone 2B,
Zone 3B, or Zone 4B
Enabled Disabled
Adjust Setpoint 175 C (350 F) 40-204 C (100-400 F)
Create/Modify Name Applicator 1: Zone 1B
Applicator 2: Zone 2B
Applicator 3: Zone 3B
Applicator 4: Zone 4B
Limited to 10 visible
characters
EcoBead Settings
Follow Mode (no EcoBead
settings used)
Basic Settings (EcoBead
enabled)
Adhesive savings: 30
(percent)
30, 40, 50, 60 (percent)
Beads per Pattern: 1 1-8
Bead Pattern: 9 0-9
Zone 1A, Zone 2A,
Zone 3A, or Zone 4A
Zone 1A, Zone 2A,
Zone 3A, or Zone 4A
Enabled Disabled
Adjust Setpoint 175 C (350 F) 40-204 C (100-400 F)
Create/Modify Name Hose 1: Zone 1A
Hose 2: Zone 2A
Hose 3: Zone 3A
Hose 4: Zone 4A
Limited to 10 visible
characters