Nordson freedom - Entering Fill Settings (contd)

Nordson freedom
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup
4-29
Part 1123087_02
 3/2014 Nordson Corporation
Table 4‐9 Fill Default and Optional Settings
Button Description Default Setting Optional Settings
Fill Flutter Delay Specifies the amount of time that
elapses after a refill signal is
received before the system
transfers adhesive from the bin to
the melter
5 (seconds) 0-1200 (seconds)
Overfill Delay Specifies how long the system can
fill before an alert is generated. This
setting is sometimes referred to as
the overfill timer. For more detailed
information on fill system alerts and
faults, refer to About Fill System
Alerts/Faults in Section 7,
Troubleshooting.
60 (seconds) 10-300 (seconds)
Audible Fill Alarm Enables or disables the audible fill
alarm that sounds when a fill
system fault is generated. Refer to
Fill System Faults in Section 7,
Troubleshooting, to troubleshoot fill
system faults.
Enabled Disabled
Alert to Fault Delay
Time
Specifies the amount of time that
can elapse after an alert is
generated (due to the Overfill Delay
time being exceeded) before a fault
is generated
4 (minutes) 1-20 (minutes)