Setup
4-31
Part 1123087_02
3/2014 Nordson Corporation
Table 4‐10 Ready Delay Default and Optional Settings
Button Description Default Setting Optional Settings
Ready Delay Specifies the amount of time to
elapse after all zones have reached
their setpoint temperatures before
the System Status button indicates
Ready/OK
NOTE: The Ready Delay begins
when all components are within
3°C (5 °F) of their setpoint
temperatures.
NOTE: The melter can perform a
warm start if it is switched on when
the zone temperatures are within
27°C (50 °F) of their setpoint
temperatures. In this case, the
Ready Delay is bypassed.
0 (minutes) 0-60 (minutes)