Setup
4-33
Part 1123087_02
3/2014 Nordson Corporation
Table 4‐11 Types of Standby (contd)
Type of Standby Description How to Use Notes
Automatic
Standby
When the following
conditions exist:
24 VDC is applied to
input 1
Input 1 is set to
Automatic Standby
A value is entered for
Auto Standby Start
Time
Auto Standby is
enabled
The system enters
automatic standby after
the input signal for
automatic standby is
removed and the amount
of time specified for Auto
Standby Start Time
elapses.
Connect wiring to supply
24 VDC to input 1, enter
an Auto Standby Start
Time setting, enable Auto
Standby.
If you want the heaters to
switch off sometime after
the system enters
automatic standby, enter
a setting for Auto
Heaters Off Time.
Refer to Automatic
Standby/Auto Heaters Off
Time Setup in this section.
If Automatic Standby
is enabled and input 1
is not supplied with 24
VDC, then the system
will be in constant
automatic standby
mode.
If all enabled
hose/applicator zones
enter zone standby,
then the system enters
automatic standby.
By default, Auto
Heaters Off Time is
disabled because the
setting is 0.
Scheduler standby When a Standby Event is
entered using the
Scheduler, the system
enters standby at the
Enter Standby time. The
system automatically exits
standby at the Exit
Standby Time.
Refer to Setting Up the
Scheduler in this section.