Table 4‐13 Zone Standby Default and Optional Settings
Button Description Default Setting Optional Settings
Off
Zone Standby
Switches Zone Standby Time On
or Off. To use this function, enter
a Zone Standby Time.
Off On
Zone Standby Time Specifies how long a hose or
applicator zone can be inactive
before it enters zone standby. To
enable this function, change
Zone Standby to On.
NOTE: Each hose/applicator
pair has its own timer. When a
hose/applicator pair is inactive
for the amount of time specified
for Zone Standby Time, the
hose/applicator pair enters zone
standby.
NOTE: When all hose/applicator
zones enter zone standby, the
system switches to automatic
standby.
60 (minutes) 0-1440 (minutes)