Repair
8-57
Part 1123087_02
î 3/2014 Nordson Corporation
1
2
3
4
Figure 8â38 Pneumatic control assembly components
1. Pneumatic control assembly
2. Retaining clip
3. Solenoid valve electrical
connector
4. Retaining screw (obscured;
see Note below)
To install the pneumatic control assembly
1. Connect all the air line tubing to the replacement pneumatic control
assembly.
2. Connect the electrical connector to the solenoid valve and tighten the
screw.
3. Slide the replacement pneumatic control assembly bracket under the
retaining clip and push up until the assembly is completely seated.
4. Secure the assembly with single retaining screw removed previously.
5. Connect the compressed air supply to the adhesive bin.
6. Enable the fill system and restore the system to normal operation.