Ferrites
P/N 1121764
P/N 1121762
18 mm D
9.8 mm D
Installation
3-33
Part 1123087_02
3/2014 Nordson Corporation
3. Plug the connectors into terminal XT7 (2) on the expansion board (1).
4. Install ferrites from the ship‐with kit around all input/output wires. Choose
the ferrite size that fits most closely around the wires.
NOTE: The procedure for setting up inputs and outputs is provided in
Section 4, Setup. Tables 4‐16 and 4‐17 provide the available control
options for each input.
NOTE: With the exception of the Pump Control option, all inputs are
transition‐based.
1234567
P/N 277908
XT7
8 9 10 11 12 13 14
P/N 277909
P/N 277909 P/N 277908
Output 1
Output 2
Output 3
Input 1
Input 2
Input 3
Input 4
3
1
2
Figure 3‐24 Connecting inputs/outputs
1. Expansion board 2. Terminal block XT7 3. Strain relief for input/output
wiring
Note: If input 4 is used, wiring must be connected to terminal 7 on connector P/N 277908 and to terminal 14 on connector
P/N277909.