Oce ColorStream - Page 258

Oce ColorStream
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
#
DescriptionArea
Protected area (must remain unprinted)1
Code segment 12
Code segment 23
Requirements
A sensor may require calibration for data integrity marks when a different developer station
or a different color is used. A message to this effect will be displayed on the operator
panel.
Requirements for sensor calibration for data integrity marks:
The user rights are available for this menu
The access ticket for this operator panel is requested
The printing system is in the 'Stop' status
No replacement function is being executed.
To Calibrate a Data Integrity Mark Sensor
#
Proceed as follows:
Click on the 'Configuration' -> 'Print parameters' -> 'Data integrity' -> 'Cali-
brate sensor' menu.
The 'Calibrate sensor' menu page opens.
1.
Select settings:
depending on the message, 'Automatic' or 'Specify mark'
depending on the message, 'Upper sensor' or 'Lower sensor'
Click the 'Next' button.
The necessary work steps are displayed.
For information on the icons displayed on the operator panel under 'Steps':
see ‘Explanation of icons’ on page 134.
Each step is described in more detail under 'Details'.
2.
Chapter 6 - Operating the Printing System258
Calibrating the Data Integrity Mark Sensor