Proceed as follows:
Carefully clean the paper width
sensor on both sides with a dry
cloth.
4.
Caution
There can be a high build-up of static charge when vacuuming the toner spill.
Always use an industrial vacuum cleaner with a grounded suction tube, rubber
nozzle and filter set for fine dust. For larger toner quantities, the industrial
vacuum cleaner must be explosion proof.
Clean the following with a vacu-
um cleaner and dry cloth:
■
Paper web tensioner and
plate opposite the paper web
tensioner
■
Paper guide plates (including
all joints, edges and ventila-
tion holes)
5.
Clean the following with a vacu-
um cleaner and dry cloth:
■
Reject roller
■
Pressure rollers
(turn the rollers to ensure
complete cleaning)
6.
Chapter 7 - Cleaning the Printing System284
Cleaning the Paper Input