12-16 Ethernet
AC30V series Variable Speed Drive
0932
DHCP To Auto IP
Type: TIME
Default: 45 seconds
Base Communications parameter.
This parameter is now obsolete.
Range RW/RO Saved Config
30 seconds
300 seconds
RW
0933
User IP Address
Type: DWORD (IP address)
Default: 0.0.0.0
Base Communications parameter.
The preferred fixed IP address of the AC30 Ethernet.
Both DHCP and Auto-IP must be disabled.
Range RW/RO Saved Config
0.0.0.0
255.255.255.255
RW
0934
User Subnet Mask
Type: DWORD (IP address)
Default: 0.0.0.0
Base Communications parameter.
The preferred fixed subnet mask of the AC30 Ethernet.
Both DHCP and Auto-IP must be disabled.
Range RW/RO Saved Config
0.0.0.0
255.255.255.255
RW