Page #169 background image
Ethernet 12-17
AC30V series Variable Speed Drive
0935
User Gateway Address
Type: DWORD (IP address)
Default: 0.0.0.0
Base Communications parameter.
The preferred fixed gateway address of the AC30 Ethernet.
Both DHCP and Auto-IP must be disabled.
Range RW/RO Saved Config
0.0.0.0
255.255.255.255
RW
0944
Web Access
Type: USINT (enumerated)
Default: (1) LIMITED
Base Communications parameter.
Enables access to the AC30 web server.
Range RW/RO Saved Config
(0) DISABLEDa web browser is prevented from accessing the AC30 web server.
(1) LIMITED a web browser may access a limited set of pages on the AC30 web server.
(2) FULL a web browser has full access to the pages on the AC30 web server, however
authentication will be required if a password has been set.
RW
0945
Web View Level
Type: USINT (enumerated)
Default: (1) TECHNICIAN
Base Communications parameter.
Sets the view level when accessing parameters via the web server.
Range RW/RO Saved Config
(0) OPERATOR
(1) TECHNICIAN
(2) ENGINEER
RW
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage