Modbus TCP A-10
AC30V series Variable Speed Drive
1458
Modbus Conn Timeout
Type: TIME
Default: 66 seconds
Base Communications Modbus TCP parameter.
Sets the Modbus connection timeout. If this parameter is set to zero then the connection will not timeout.
Range Writable Saved Config
0
100 000 seconds
1567
Modbus Mapping
Type: Array of UINT
Default: none
Base Communications Modbus TCP parameter.
User-defined Modbus parameter mapping table. Each entry in the table represents the required parameter number.
Range Writable Saved Config
0
Last parameter number.
1632
Mapping Valid
Type: BOOL
Base Communications Modbus TCP parameter.
Status of the user defined mapping area. This will be set to TRUE if all entries in the mapping table are valid.
Range Writable Saved Config
FALSE
TRUE