Parameter Reference D-91
AC30V series Variable Speed Drive
PNO Parameter Descriptions
0498 Ramping Active
Set TRUE when ramping.
0499 Ramp Spd Setpoint Input
Input speed setpoint to the ramp
0500 Ramp Speed Output
Output speed
0501 Jog Setpoint
The setpoint is the target reference that the Drive will ramp to
0502 Jog Acceleration Time
The time that the Drive will take to ramp the jog setpoint from 0.00% to 100.00%.
0503 Jog Deceleration Time
The time that the Drive will take to ramp the jog setpoint from 100.00% to 0.00%.
0504 Stop Ramp Time
Rate at which the demand is ramped to zero after the ramp has been quenched
0505 Zero Speed Threshold
Hold for zero speed detection used by stop sequences
0506 Zero Speed Stop Delay
Sets the time at which the Drive holds zero speed before quenching after a normal stop or a jog stop. This may be particularly useful
if a mechanical brake requires time to operate at zero speed, or for jogging a machine to position
0507 Quickstop Time Limit
Maximum time that the Drive will try to Quickstop, before quenching
0508 Quickstop RampTime
Rate at which the
Speed Demand
is ramped to zero when Quickstop is active
0509 Final Stop Rate
Rate at which any internally generated setpoint trims are removed. For example, the trim due to the slip compensation in Volts/Hz
control mode.
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals