Loading...
Parameter Reference D-133
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes
MBus
0258
Autotune Test Disable.Stator Resistance
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6
01043
0259
Autotune Test Disable.Leakage Inductance
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6
01045
0260
Autotune Test Disable.Magnetising Current
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6
01047
0261
Autotune Test Disable.Rotor Time Constant
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6
01049
0262
Autotune Test Disable.Encoder Direction
Same as PNO 255
BOOL
FALSE
STOPPED
TECHNICIAN
6
01051
0274
Autotune Ramp Time
Same as PNO 255
TIME
10.000
1.000 to 1000.000
s
STOPPED
TECHNICIAN
6
01075
0305
Current Limit
Setup::Motor Control::Control and Type
Parameters::Motor Control::Current Limit
REAL 150.0 0.0 to 300.0 % ALWAYS TECHNICIAN
01137
0307
Regen Limit Enable
Parameters::Motor Control::Current Limit
BOOL
TRUE
ALWAYS
ENGINEER
01141
0310
VHz Flying Start Enable
Parameters::Motor Control::Flycatching
BOOL
FALSE
ALWAYS
TECHNICIAN
01147
0311
VC Flying Start Enable
Parameters::Motor Control::Flycatching
BOOL
FALSE
ALWAYS
TECHNICIAN
01149
0312
Flying Start Mode Parameters::Motor Control::Flycatching
USINT
(enum)
0
0:ALWAYS
1:TRIP OR POWER UP
2:TRIP
ALWAYS TECHNICIAN
01151
0313
Search Mode Parameters::Motor Control::Flycatching
USINT
(enum)
0
0:BIDIRECTIONAL
1:UNIDIRECTION
ALWAYS TECHNICIAN
01153
0314
Search Volts
Parameters::Motor Control::Flycatching
REAL
9.0
0.0 to 100.0
%
ALWAYS
TECHNICIAN
6
01155
0315
Search Boost
Parameters::Motor Control::Flycatching
REAL
40.0
0.0 to 50.0
%
ALWAYS
TECHNICIAN
6
01157
0316
Search Time
Parameters::Motor Control::Flycatching
TIME
3.000
0.100 to 60.000
s
ALWAYS
TECHNICIAN
6
01159
0317
Min Search Speed
Parameters::Motor Control::Flycatching
REAL
5
0 to 500
Hz
ALWAYS
TECHNICIAN
01161
0318
Flying Reflux Time
Parameters::Motor Control::Flycatching
TIME
2.000
0.100 to 10.000
s
ALWAYS
TECHNICIAN
6
01163
0324
DC Inj Deflux Time
Parameters::Motor Control::Inj Braking
TIME
0.500
0.100 to 20.000
s
ALWAYS
TECHNICIAN
6
01175
0325
DC Inj Frequency Parameters::Motor Control::Inj Braking REAL 9 1 to 500 Hz ALWAYS TECHNICIAN 6
0117
7
0326
DC Inj Current Limit Parameters::Motor Control::Inj Braking REAL 100.0 50.0 to 150.0 % ALWAYS TECHNICIAN 6
0117
9
0327
DC Pulse Time Parameters::Motor Control::Inj Braking TIME 2.000 0.000 to 100.000 s ALWAYS TECHNICIAN 6
0118
1
0328
Final DC Pulse Time
Parameters::Motor Control::Inj Braking
TIME
1.000
0.000 to 10.000
s
ALWAYS
TECHNICIAN
6
01183
0329
DC Current Level
Parameters::Motor Control::Inj Braking
REAL
3.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
6
01185
0330
DC Inj Timeout
Parameters::Motor Control::Inj Braking
TIME
90.000
0.000 to 600.000
s
ALWAYS
TECHNICIAN
6
01187
0331
DC Inj Base Volts
Parameters::Motor Control::Inj Braking
REAL
100.00
0.00 to 115.47
%
ALWAYS
TECHNICIAN
6
01189
0332
100% Mot Current
Parameters::Motor Control::Motor Load
REAL
x.x
0.0 to 10000.0
NEVER
TECHNICIAN
01191
0333
Mot Inv Time Overl'd
Parameters::Motor Control::Motor Load
REAL
x.
0 to 500
%
NEVER
TECHNICIAN
01193
0334
Mot Inv Time Delay
Parameters::Motor Control::Motor Load
TIME
0.000 to 100000.000
s
NEVER
TECHNICIAN
01195
0335
Mot Inv Time Warning
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
01197
0336
Mot Inv Time Active
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
01199
0337
Mot Inv Time Output %
Parameters::Motor Control::Motor Load
REAL
x.x
0.0 to 500.0
%
NEVER
TECHNICIAN
01201
0338
Mot I2T TC
Parameters::Motor Control::Motor Load
TIME
0.000 to 1000000.000
s
NEVER
TECHNICIAN
01203
0339
Actual Mot I2T Output
Parameters::Motor Control::Motor Load
REAL
x.x
0.0 to 500.0
%
NEVER
TECHNICIAN
01205
0340
Mot I2T Active
Parameters::Motor Control::Motor Load
BOOL
NEVER
OPERATOR
01207
0341
Mot I2T Warning
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
01209
0342
Mot I2T Enable
Parameters::Motor Control::Motor Load
BOOL
NEVER
TECHNICIAN
01211
0343
100% Stk Current
Parameters::Motor Control::Stack Inv Time
REAL
x.x
0.0 to 10000.0
A
NEVER
TECHNICIAN
01213
0344
Long Overload Level
Parameters::Motor Control::Stack Inv Time
REAL
x.
0 to 200
%
NEVER
TECHNICIAN
01215
0345
Long Overload Time
Parameters::Motor Control::Stack Inv Time
TIME
0.000 to 100000.000
s
NEVER
TECHNICIAN
01217
0346
Short Overload Level
Parameters::Motor Control::Stack Inv Time
REAL
x.
0 to 200
%
NEVER
TECHNICIAN
01219
0347
Short Overload Time
Parameters::Motor Control::Stack Inv Time
TIME
0.000 to 10000.000
s
NEVER
TECHNICIAN
01221
0348
Inv Time Aiming Point
Parameters::Motor Control::Stack Inv Time
REAL
x.
0 to 200
%
NEVER
TECHNICIAN
01223
0349
Inv Time Output
Parameters::Motor Control::Stack Inv Time
REAL
x.
0 to 500
%
NEVER
TECHNICIAN
01225
0350
Inv Time Up Rate
Parameters::Motor Control::Stack Inv Time
TIME
5.000
0.000 to 120.000
s
STOPPED
ENGINEER
01227
0351
Inv Time Down Rate
Parameters::Motor Control::Stack Inv Time
TIME
5.000
0.000 to 120.000
s
STOPPED
ENGINEER
01229
0352
Inv Time Warning
Parameters::Motor Control::Stack Inv Time
BOOL
NEVER
TECHNICIAN
01231
0353
Inv Time Active
Parameters::Motor Control::Stack Inv Time
BOOL
NEVER
TECHNICIAN
01233
0354
Slip Compensatn Enable
Parameters::Motor Control::Slip Compensation
BOOL
FALSE
ALWAYS
TECHNICIAN
01235
0356
SLP Motoring Limit
Parameters::Motor Control::Slip Compensation
REAL
150
0 to 600
RPM
ALWAYS
TECHNICIAN
6
01239