D-138 Parameter Reference
AC30V series Variable Speed Drive
App Control Word.SWITCH ON
Parameters::Motor Control::Sequencing
App Control Word.ENABLE VOLTAGE
Parameters::Motor Control::Sequencing
App Control Word.NOT QUICKSTOP
Parameters::Motor Control::Sequencing
App Control Word.ENABLE OPERATION
Parameters::Motor Control::Sequencing
App Control Word.RESET FAULT
Parameters::Motor Control::Sequencing
App Control Word.EXTERNAL FAULT
Parameters::Motor Control::Sequencing
App Control Word.USE JOG REFERENCE
Parameters::Motor Control::Sequencing
App Control Word.REVERSE DIRECTION
Parameters::Motor Control::Sequencing
App Control Word.AUTO INITIALISE
Parameters::Motor Control::Sequencing
App Control Word.EVENT TRIGGERED OP
Parameters::Motor Control::Sequencing
0627
Comms Control Word Parameters::Motor Control::Sequencing
WORD
(bitfield)
0000
1:ENABLE VOLTAGE
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
8:EXTERNAL FAULT
10:USE COMMS CONTROL
11:USE COMMS
REFERENCE
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
ALWAYS TECHNICIAN 2
01781
Comms Control Word.SWITCH ON
Parameters::Motor Control::Sequencing
Comms Control Word.ENABLE VOLTAGE
Parameters::Motor Control::Sequencing
Comms Control Word.NOT QUICKSTOP
Parameters::Motor Control::Sequencing
Comms Control Word.ENABLE OPERATION
Parameters::Motor Control::Sequencing
Comms Control Word.RESET FAULT
Parameters::Motor Control::Sequencing
Comms Control Word.EXTERNAL FAULT
Parameters::Motor Control::Sequencing
0638
Comms Control Word.USE COMMS
CONTROL
Parameters::Motor Control::Sequencing BOOL FALSE ALWAYS TECHNICIAN 2
01803
0639
Comms Control Word.USE COMMS
REFERENCE
Parameters::Motor Control::Sequencing BOOL FALSE ALWAYS TECHNICIAN 2
01805
0640
Comms Control Word.USE JOG
REFERENCE
Parameters::Motor Control::Sequencing BOOL FALSE ALWAYS TECHNICIAN 2
01807
Comms Control Word.REVERSE DIRECTION
Parameters::Motor Control::Sequencing
Comms Control Word.AUTO INITIALISE
Parameters::Motor Control::Sequencing
0643
Comms Control Word.EVENT TRIGGERED
OP
Parameters::Motor Control::Sequencing BOOL FALSE ALWAYS TECHNICIAN 2
01813
0644
Control Word Parameters::Motor Control::Sequencing
WORD
(bitfield)
1:ENABLE VOLTAGE
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
8:EXTERNAL FAULT
10:USE COMMS CONTROL
11:USE COMMS
REFERENCE
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
NEVER TECHNICIAN
01815
Parameters::Motor Control::Sequencing
Control Word.ENABLE VOLTAGE
Parameters::Motor Control::Sequencing
Control Word.NOT QUICKSTOP
Parameters::Motor Control::Sequencing
Control Word.ENABLE OPERATION
Parameters::Motor Control::Sequencing
Parameters::Motor Control::Sequencing