Parameter Reference D-155
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes
MBus
1632
Mapping Valid
Monitor::Communications::Base Modbus
Parameters::Base Comms::Modbus
BOOL NEVER OPERATOR
03791
1633
Application User Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 25.00
%
ALWAYS
OPERATOR
03793
1634
Start Delay
Parameters::Motor Control::Motor Sequencer
TIME
0.000
0.000 to 30.000
s
STOPPED
TECHNICIAN
03795
1635
Delay To Start
Parameters::Motor Control::Motor Sequencer
TIME
0.000 to Max
s
NEVER
TECHNICIAN
03797
1636
Manufacturing Flags
Parameters::Device Manager::Drive info
WORD
NEVER
ENGINEER
03799
1637
Engineer Password
Parameters::Keypad::Graphical Keypad
WORD
0000
ALWAYS
TECHNICIAN
03801
1641
VDC Lim Enable
Parameters::Motor Control::DC Link Volts Limit
BOOL
FALSE
STOPPED
TECHNICIAN
03809
1642
VDC Lim Level
Parameters::Motor Control::DC Link Volts Limit
REAL
91
78 to 100
%
STOPPED
TECHNICIAN
03811
1643
VDC Lim Active
Parameters::Motor Control::DC Link Volts Limit
BOOL
NEVER
TECHNICIAN
03813
1644
VDC Lim Output
Parameters::Motor Control::DC Link Volts Limit
REAL
x.
Min to Max
Hz
NEVER
ENGINEER
03815
1645
Pwrl Enable
Parameters::Motor Control::Power Loss Ride Thru
BOOL
FALSE
STOPPED
TECHNICIAN
03817
1646
Pwrl Trip Threshold
Parameters::Motor Control::Power Loss Ride Thru
REAL
52.0
20.0 to 60.0
STOPPED
TECHNICIAN
03819
1647
Pwrl Control Band
Parameters::Motor Control::Power Loss Ride Thru
REAL
2.0
0.0 to 20.0
STOPPED
TECHNICIAN
03821
1648
Pwrl Accel Rate
Parameters::Motor Control::Power Loss Ride Thru
REAL
100
1 to 500
Hz/s
STOPPED
TECHNICIAN
03823
1649
Pwrl Decel Rate
Parameters::Motor Control::Power Loss Ride Thru
REAL
100
1 to 500
Hz/s
STOPPED
TECHNICIAN
03825
1650
Pwrl Time Limit
Parameters::Motor Control::Power Loss Ride Thru
TIME
30.000
0.000 to 300.000
s
STOPPED
TECHNICIAN
03827
1651
Pwrl Active
Parameters::Motor Control::Power Loss Ride Thru
BOOL
NEVER
TECHNICIAN
03829
1658
Current Diff Level
Parameters::Trips::Current Sensor Trip
REAL
25.00
0.00 to 100.00
%
ALWAYS
OPERATOR
03843
1900
Selected Application USINT (enum)
0
0:BASIC SPEED CONTROL
1:AUTO/MANUAL
CONTROL
2:SPEED RAISE / LOWER
3:SPEED PRESETS
4:PROCESS PID
ALWAYS TECHNICIAN
5
04327
1901
RL Ramp Time
Setup::Application::Raise Lower
TIME
10.0
0.0 to 600.0
s
ALWAYS
TECHNICIAN
5,8
04329
1902
RL Reset Value
Setup::Application::Raise Lower
REAL
0.0
-500.0 to 500.0
%
ALWAYS
TECHNICIAN
5,8
04331
1903
RL Maximum Value
Setup::Application::Raise Lower
REAL
100.0
-500.0 to 500.0
%
ALWAYS
TECHNICIAN
5,8
04333
1904
RL Minimum Value
Setup::Application::Raise Lower
REAL
-100.0
-500.0 to 500.0
%
ALWAYS
TECHNICIAN
5,8
04335
1905
Raise Lower Output
Monitor::Application::Raise Lower
REAL
0.0
-500.0 to 500.0
NEVER
TECHNICIAN
1,8
04337
1906
Minimum Speed Value
Setup::Application::Minimum Speed
REAL
-100.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04339
1907
Minimum Speed Mode Setup::Application::Minimum Speed USINT (enum)
0
0:PROP WITH MINIMUM
1:LINEAR
ALWAYS TECHNICIAN
5,8
04341
1908
Skip Band 1
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04343
1909
Skip Frequency 1
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04345
1910
Skip Band 2
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04347
1911
Skip Frequency 2
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04349
1912
Skip Band 3
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04351
1913
Skip Frequency 3
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04353
1914
Skip Band 4
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04355
1915
Skip Frequency 4
Setup::Application::Skip Frequencies
REAL
0.0
0.0 to 1000.0
Hz
ALWAYS
TECHNICIAN
5,8
04357
1916
Preset Speed 0
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04359
1917
Preset Speed 1
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04361
1918
Preset Speed 2
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04363
1919
Preset Speed 3
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04365
1920
Preset Speed 4
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04367
1921
Preset Speed 5
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04369
1922
Preset Speed 6
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04371
1923
Preset Speed 7
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS
TECHNICIAN
5,8
04373
1924
Selected Preset
Monitor::Application::Preset Speeds
USINT
0 to 7
NEVER
TECHNICIAN
8
04375
1925
Preset Speed Output
Monitor::Application::Preset Speeds
REAL
-100.0 to 100.0
%
NEVER
TECHNICIAN
8
04377
1926
PID Setpoint Negate
Setup::Application::PID
BOOL
TRUE
ALWAYS
TECHNICIAN
5,8
04379
1927
PID Feedback Negate
Setup::Application::PID
BOOL
TRUE
ALWAYS
TECHNICIAN
5,8
04381
1928
PID Proportional Gain
Setup::Application::PID
REAL
1.0
ALWAYS
TECHNICIAN
5,8
04383
1929
PID Integral TC
Setup::Application::PID
TIME
1.00
0.01 to 100.00
s
ALWAYS
TECHNICIAN
5,8
04385
1930
PID Derivative TC
Setup::Application::PID
TIME
0.000
0.000 to 10.000
s
ALWAYS
TECHNICIAN
5,8
04387
www.comoso.com

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage
CommunicationRS485

Related product manuals