D-154 Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes
MBus
1543
Clone Status Same as PNO 1534
USINT
(enum)
0:IDLE
1:SAVING
2:RESTORING
3:VERIFYING
4:DONE
5:CANNOT START
6:FAILED
7:NO SD CARD
8:VERIFY FAILED
9:FILE NOT OPENED
10:FILE INCOMPATIBLE
11:FILE FAILURE
12:POWER MISMATCH
13:APPLICATION FAILURE
14:PARAMETERS FAILURE
NEVER TECHNICIAN
03613
1544
Filter Type
Parameters::Motor Control::Filter On Torque
Dmd
USINT
(enum)
0
0:NONE
1:MAX ATTENUATION
2:MINIMUM PHASE
3:PHASE ADVANCE
4:NOTCH
ALWAYS TECHNICIAN
03615
1545
Cut Off Frequency
Parameters::Motor Control::Filter On Torque
Dmd
REAL 2000 20 to 6000 Hz ALWAYS TECHNICIAN
03617
1546
Frequency 1
Parameters::Motor Control::Filter On Torque
Dmd
REAL 2000 20 to 6000 Hz ALWAYS TECHNICIAN
03619
1547
Frequency 2
Parameters::Motor Control::Filter On Torque
Dmd
REAL 2000 20 to 6000 Hz ALWAYS TECHNICIAN
03621
1548
Factor
Parameters::Motor Control::Filter On Torque
Dmd
REAL 0.20 0.10 to 1.00 ALWAYS TECHNICIAN
03623
1549
Application Volts
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 150.00
%
ALWAYS
OPERATOR
03625
1550
Nameplate Mag Current
Setup::Motor Control::Autotune
Parameters::Motor Control::Autotune
REAL 1.00 0.01 to 1000.00 A STOPPED TECHNICIAN 6
03627
1551
Product Code Flags
Parameters::Device Manager::Drive info
BYTE
NEVER
ENGINEER
03629
1554
Application Name
Parameters::Application::App Info
STRING[20]
NEVER
TECHNICIAN
03635
1560
Start Delay Enable
Parameters::Motor Control::Motor Sequencer
BOOL
FALSE
STOPPED
TECHNICIAN
03647
1565
Local Power Up Mode Parameters::Motor Control::Sequencing
USINT
(enum)
0
0:AS WHEN POWERED
DOWN
1:LOCAL
2:REMOTE
ALWAYS TECHNICIAN
03657
1567
Modbus Mapping
Setup::Communications::Base Modbus
Parameters::Base Comms::Modbus
ARRAY[0..15] ALWAYS ENGINEER
03661
1568
Modbus Mapping[0]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03663
1569
Modbus Mapping[1]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03665
1570
Modbus Mapping[2]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03667
1571
Modbus Mapping[3]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03669
1572
Modbus Mapping[4]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03671
1573
Modbus Mapping[5]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03673
1574
Modbus Mapping[6]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03675
1575
Modbus Mapping[7]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03677
1576
Modbus Mapping[8]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03679
1577
Modbus Mapping[9]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03681
1578
Modbus Mapping[10]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03683
1579
Modbus Mapping[11]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03685
1580
Modbus Mapping[12]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03687
1581
Modbus Mapping[13]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03689
1582
Modbus Mapping[14]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03691
1583
Modbus Mapping[15]
Same as PNO 1567
UINT
0000
0000 to 2149
ALWAYS
ENGINEER
03693