Section 22: HEATING AND AIR CONDITIONING
PA1553
59
Prevost number...................................................................................................................................950382
Compressor unloader valve
Make................................................................................................................................... Carrier Transicold
Type .........................................................................................................................................Electric (AMC)
Voltage............................................................................................................................................. 24 V DC)
Watts ...........................................................................................................................................................15
Prevost number (without coil) .............................................................................................................950095
Coil Prevost numbert...........................................................................................................................950096
Magnetic clutch
Make................................................................................................................................... Carrier Transicold
Type ...................................................................................................Housing mounted 9” dia., 2-B grooves
Voltage.............................................................................................................................................. 24 V DC
Coil resistance at 68
o
F (20
o
C)........................................................................................... 5.15 – 5.69 ohms
Prevost number...................................................................................................................................950204
Compressor V belts
Make......................................................................................................................................................Dayco
Model (matching set of 2) ...................................................................................................................... BX97
Prevost number (with Delco 270/300 Amp Alternator) .......................................................................506664
Compressor V belt
Make......................................................................................................................................................Dayco
Model.................................................................................................................................................... BX100
Prevost number (with two BOSH Alternators) ....................................................................................506681
Condenser coil (Central system)
Make................................................................................................................................... Carrier Transicold
Aluminum
Prevost number...................................................................................................................................870654
Copper
Prevost number...................................................................................................................................870729
Evaporator coil (Central system)
Make................................................................................................................................... Carrier Transicold
Prevost number...................................................................................................................................871070