Section 26: XLII SLIDE-OUT
PA1553
19
AIR PRESSURE
INLET VALVE
FIGURE 28 : FRONT SERVICE COMPARTMENT
14.2 MAINTENANCE
COMPRESSED AIR LINE
Inspect all compressed air line tubing for cut,
swelling, kink or other damage or deterioration.
Inspect the pneumatic fittings and components
for any leak. The slide-out air supply is
connected to the accessory air tank and the
maintenance is specified in the “brake and air
system” section from the Prevost maintenance
manual.
INFLATABLE SEAL CIRCUIT
The efficiency of the seal could be affected by
impurities, such as white powder in the
pneumatic control valve. It is recommended to
inspect the inflatable seal control components
once a year to prevent malfunction. In this case,
remove the seal valves and clean the interior
valve components using a compressed air
nozzle. Do the same thing with the vacuum
generators.
The inflatable seal pressure must be set from 7
to 10 psi maximum. It is recommended to check
the inflatable seal pressure once a month to
ensure sealing efficiency and prevent any
infiltration from outside.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST LE MIRAGE XLII BUS SHELLS and is the answer not in the manual?

PREVOST LE MIRAGE XLII BUS SHELLS Specifications

General IconGeneral
BrandPREVOST
ModelLE MIRAGE XLII BUS SHELLS
CategoryBuses
LanguageEnglish

Related product manuals