EasyManuals Logo

PREVOST LE MIRAGE XLII BUS SHELLS User Manual

PREVOST LE MIRAGE XLII BUS SHELLS
1342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1312 background imageLoading...
Page #1312 background image
Section 26: XLII SLIDE-OUT
PA1553
18
3. Remove the 2 upper acetal plastic blocks.
They have holes so they can be removed
with a picking tool (FIGURE 26) from outside
the vehicle. If the acetal plastic blocks are
too hard to reach, slightly extend the slide-
out, the movement of the slide-out should
bring them out.
4. To remove the lower acetal plastic block,
gain access to the compartment under it.
Slide the acetal plastic block toward the
center of the slide-out. Proceed the same
way to reinstall it.
5. Reinstalling the upper acetal plastic blocks.
Fold the wiper seal toward the outside with a
flat tool to ease installation (FIGURE 27).
Tighten the mounting screws to a torque of 7
ft-lb. Leave no gap between the blocks and
the rail.
FIGURE 27: LOWER ACETAL PLASTIC BLOCK
INSERTION
14 SLIDE-OUT PNEUMATIC
SYSTEM
The slide-out is controlled by a pneumatic and
electrical system. Mainly, the pneumatic system
consists of electrically operated valves that
control slide-out components and safety
operations.
14.1 DESCRIPTION
AIR PRESSURE INLET VALVE
The slide-out air pressure comes from the air
pressure inlet valve on the pneumatic panel in
the front service compartment (figure 28).
INFLATABLE SEAL VALVE
The inflation and the deflation of a seal are done
using a 5-port 2-position manifold valve with two
solenoids. One solenoid is used for inflating of
the seal and the other for deflating of the seal.
When one of the solenoids is activated (seal
deflating valve for example), the valve will keep
its state even if the solenoid is deactivated. The
inflating valve solenoid is activated to re-inflate
the seal when the slide-out reaches its inner or
outer limit. The inflatable seal pressure is set to
10 psi and in full “IN” or full “OUT” position, this
pressure is continuously applied to the seal as
long as the accessory air tank (which supply the
slide-out) is not empty.
VACUUM GENERATOR
A vacuum generator using Venturi principle is
controlled by a 5-port 2-position manifold valve
and is used to evacuate the air faster from the
seal and to ensure that the seal surface does not
stay in contact with the slide-out.
The vacuum generator valve is activated
simultaneously with seal deflating valve solenoid
for 10 seconds. A pressure transducer will detect
a seal, vacuum valve or generator failure if -5
psig is not reached after the 10 seconds delay.
In that situation, an error code will be stored in
the MCD (message center display). In normal
operating condition, -5 psig is a necessary
condition to consider the seal as deflated.
NOTE
When air pressure is relieved using the shut-
off valve, the normal extending and retracting
operation cycle is disabled, because the
pressure transducer reads 0 psig and that is
higher than -5 psig (vacuum). For that reason
the slide-out cannot be moved with the
handheld control.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST LE MIRAGE XLII BUS SHELLS and is the answer not in the manual?

PREVOST LE MIRAGE XLII BUS SHELLS Specifications

General IconGeneral
BrandPREVOST
ModelLE MIRAGE XLII BUS SHELLS
CategoryBuses
LanguageEnglish

Related product manuals