Repair and Testing Instructions for T1 Page 11
Alternator 0120 689 552 Edition 001
All rights rest with Robert Bosch Corp, including patent rights. All rights of use of reproduction and publication rest with R. B. Corp.
UA/ASV 04.12.98 T1ALTFinal.DOC
6 Parts Cleaning
Caution: Fire Risk
To provide radio interference suppression, the alternator is equipped with capacitors with a long storage time.
Cleaning of alternator components may cause and electrical discharge when they are immersed in cleaning
fluid. This discharge may cause combustible liquids to ignite.
Alternator components with capacitors should only be cleaned with a non-combustible cleaner such as HAKU
1025/6.
Caution: Compressed Air
Only use compressed air regulated to a maximum of 4 Bar (60 PSI), and a clean cloth for cleaning of the
armature, excitation windings and alternator plates.
Caution: Explosion Risk
Avoid exposure to fire, open flame and sparks. Thoroughly dry all cleaned parts as gases could form from the
cleaning process and may cause an explosion.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST LE MIRAGE XLII BUS SHELLS and is the answer not in the manual?

PREVOST LE MIRAGE XLII BUS SHELLS Specifications

General IconGeneral
BrandPREVOST
ModelLE MIRAGE XLII BUS SHELLS
CategoryBuses
LanguageEnglish

Related product manuals