EasyManuals Logo

PREVOST LE MIRAGE XLII BUS SHELLS User Manual

PREVOST LE MIRAGE XLII BUS SHELLS
1342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #355 background imageLoading...
Page #355 background image
FAULT CODE MANUAL Created on 00-04-25 15:30
- 11 -
MID (P)PID/SID FMI Seriousness Component/Function Display text
136 SID 5 1 Air gap -
136 SID 5 2 Incorrect tyre -
136 SID 5 3 Shorted to UBATT -
136 SID 5 4 Shorted to ground -
136 SID 5 5 Open circuit -
136 SID 5 6 Short circuit -
136 SID 5 7 Incorrect pole wheel -
136 SID 5 8 Slip -
136 SID 5 9 Wires mismatched -
136 SID 5 10 Speed drop-out -
136 SID 5 11 Abnormal speed -
136 SID 5 12 Frequency too high -
136 SID 6 1 Air gap -
136 SID 6 2 Incorrect tyre -
136 SID 6 3 Shorted to UBATT -
136 SID 6 4 Shorted to ground -
136 SID 6 5 Open circuit -
136 SID 6 6 Short circuit -
136 SID 6 7 Incorrect pole wheel -
136 SID 6 8 Slip -
136 SID 6 9 Wires mismatched -
136 SID 6 10 Speed drop-out -
136 SID 6 11 Abnormal speed -
136 SID 6 12 Frequency too high -
136 SID 7 1 Open circuit in- and outlet Modulator valve LF
136 SID 7 3 Shorted to UBATT Modulator valve LF
136 SID 7 5 Open circuit Modulator valve LF
136 SID 7 6 Shorted to ground Modulator valve LF
136 SID 8 1 Open circuit in- and outlet Modulator valve RF
136 SID 8 3 Shorted to UBATT Modulator valve RF
136 SID 8 5 Open circuit Modulator valve RF
136 SID 8 6 Shorted to ground Modulator valve RF
136 SID 9 1 Open circuit in- and outlet Modulator valve L1R
136 SID 9 3 Shorted to UBATT Modulator valve L1R
136 SID 9 5 Open circuit Modulator valve L1R
136 SID 9 6 Shorted to ground Modulator valve L1R
136 SID 10 1 Open circuit in- and outlet Modulator valve R1R
136 SID 10 3 Shorted to UBATT Modulator valve R1R
136 SID 10 5 Open circuit Modulator valve R1R
136 SID 10 6 Shorted to ground Modulator valve R1R
136 SID 11 1 Open circuit in- and outlet -
136 SID 11 3 Shorted to UBATT -
136 SID 11 5 Open circuit -
136 SID 11 6 Shorted to ground -
136 SID 12 1 Open circuit in- and outlet -
136 SID 12 3 Shorted to UBATT -
136 SID 12 5 Open circuit -
136 SID 12 6 Shorted to ground -
136 SID 13 3 Shorted to UBATT Retard contr relay
136 SID 13 5 Open circuit Retard contr relay
136 SID 13 6 Shorted to ground Retard contr relay
136 SID 14 3 Ground diagonal, shorted to
UBATT
Valve relay

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PREVOST LE MIRAGE XLII BUS SHELLS and is the answer not in the manual?

PREVOST LE MIRAGE XLII BUS SHELLS Specifications

General IconGeneral
BrandPREVOST
ModelLE MIRAGE XLII BUS SHELLS
CategoryBuses
LanguageEnglish

Related product manuals