SmartStor NS4600 Product Manual
314
System was shut down
abnormally.
The SmartStor shut down incorrectly the last time.
See “Shutting Down the SmartStor” on page 271.
CPU temperature is
higher than 58°C/138°F.
System will shut down.
Allow the SmartStor to cool for several minutes. Then
restart the SmartStor and check system temperature
and fan operation. See page 275.
Be sure there is adequate air circulation around the
SmartStor.
System fan speed is lower
than 1800 RPM. Check
the system before
continuing.
Try enabling or disabling the Smart Fan. See
page 275. If the fan still runs below 1800 RPM,
contact Technical Support. See page 329.
AC Power failure. System
will shut down.
Restore the AC power. Then restart the SmartStor.
See “Connecting the Power” on page 10.
Disk Drives
Task X timeout on disk Y
at LBA [address]
A LBA error. Check the disk drives. See page 306.
Check the RAID Volume. See page 308. Replace the
disk drive or rebuild the RAID Volume as needed.
Task X disk error on disk
Y at LBA [address] with
status Z
S.M.A.R.T threshold
exceeded on disk X
Check the disk drives. See page 306. Replace the
failed drive. See page 307.
BSL update on disk X at
LBA [address]
Bad sector on a disk drive. Check the disk drives.
See page 306. Replace the disk drive if it continues to
receive BSL updates.
BSL log disk X at LBA
[address] cleared
Check the disk drives. See page 306.
Delete Spare Disk Delete a spare drive. Normal.
RAID Volumes
Create [RAID name,
RAID level and X number
of disk drives]
Create a RAID Volume. Normal.
Delete RAID X Delete a RAID Volume. Normal.
Migration or Rebuilding
on array X started.
RAID Volume Migration or Rebuild has started.
Normal.
Migration or Rebuilding
on array X at Y%.
Progress report on RAID Volume Migration or
Rebuild. Normal.
Reported Event Corrective Action

Table of Contents

Other manuals for Promise Technology Smartstor NS4600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Smartstor NS4600 and is the answer not in the manual?

Promise Technology Smartstor NS4600 Specifications

General IconGeneral
RAID levels0, 1, 5, 10
Storage drive size3.5 \
Hot-swap drive baysYes
Storage drive capacity0 GB
Supported file systemsEXT3, FAT32
Storage drive interfaceSerial ATA II
Total installed storage capacity0 TB
Number of storage drives installed4
Internal memory0.25 GB
Processor model-
Processor frequency0.6 GHz
Maximum data transfer rate1000 Mbit/s
Supported network protocolsFTP, DHCP, NTP
Compliance industry standardsIEEE 802.3i, IEEE 802.3ab, IEEE 802.3u
CertificationRoHS, CE, FCC, UL, TUV
Data transfer rate3 Gbit/s
Dimensions (WxDxH)152.5 x 229.6 x 188.2 mm
Power requirements100 - 230 V/50-60 Hz
Networking featuresGigabit Ethernet
Compatible operating systemsWindows 2000/XP/2003/Vista Mac x 10.4 + Linux
USB 2.0 ports quantity2
Ethernet LAN (RJ-45) ports1
Power supply unit (PSU) capacity90 W
Operating temperature (T-T)5 - 35 °C
Operating relative humidity (H-H)10 - 85 %
Weight and Dimensions IconWeight and Dimensions
Weight2500 g