Rockwell Automation Publication 2198-UM002L-EN-P - October 2021 77
Chapter 3
Mount the Kinetix 5700 Drive System
This chapter provides installation procedures for mounting your Kinetix® 5700
drive system to the system panel and installing DC-bus links and 24V shared-
bus connector kits to the drive modules.
This procedure assumes that you have prepared your panel and understand
how to bond your system. For installation instructions regarding equipment
and accessories not included here, refer to the instructions that came with
those products.
Topic Page
Determine Mounting Order 78
Mount Accessory Modules 81
Zero-stack Tab and Cutout 82
Install Shared-bus Connection Systems 82
Drill-hole Patterns 85
Mount Your Kinetix 5700 Drive Modules 88
SHOCK HAZARD: To avoid the hazard of electrical shock, perform all
mounting and wiring of the Kinetix 5700 drive system before applying
power. Once power is applied, connector terminals can have voltage
present even when not in use.
ATTENTION: Plan the installation of your system so that you can perform all
cutting, drilling, tapping, and welding with the system removed from the
enclosure. Because the system is of the open type construction, be careful
to keep metal debris from falling into it. Metal debris or other foreign matter
can become lodged in the circuitry and result in damage to the components.