EasyManua.ls Logo

Rockwell Automation Allen-Bradley Kinetix 5700 - Motor Control Feature Support

Rockwell Automation Allen-Bradley Kinetix 5700
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
398 Rockwell Automation Publication 2198-UM002L-EN-P - October 2021
Appendix F Motor Control Feature Support
Frequency Control Methods The Kinetix 5700 servo drives support three open-loop frequency control
methods. These are the choices:
Basic Volts/Hertz - This method is used in single asynchronous-motor
applications
Basic Volts/Hertz - Fan Pump - This method is similar to Basic Volts/
Hertz, but is specifically tailored for fan/pump applications
Sensorless Vector with Slip Compensation - This method is used for
most constant torque applications. Provides excellent starting,
acceleration, and running torque
To configure your induction motor in the Logix Designer application, refer to
Configure Induction-motor Frequency-control Axis Properties
on page 223.
Open-loop frequency control is suitable in applications such as conveyors,
pumps, and fans. Features include the following:
Start Boost and Run Boost
Electronic motor thermal-overload protection per Class 10 requirements
Two skip frequencies, in which the drive does not operate
All three-phase induction motors, suitable for variable speed drive (VFD)
operation, are supported
Table 197 - Motor Specifications
Attribute Value
Output frequency, max 590 Hz
Pole pairs, max 50
Motor cable length, max
90 m (295 ft)
(1)
(1) Applies to all Kinetix 5700 drives and compatible motors/actuators with Hiperface and Hiperface DSL high-resolution
absolute feedback. For compatible motors/actuators with incremental feedback, 30 m (98 ft) is the maximum cable length.