Section 07 ELECTRICAL SYSTEM
Subsection 02 (CHARGING SYSTEM)
smr2005-058-007_a
If any result is out of specification, replace sta-
tor.
Replug connectors properly.
Insulation
Disconnect the magneto wiring harness con-
nector.
smr2005-058-006_a
Install the 4-pin magneto harness adapter
(P/N 295 000 131) to the magneto wiring har-
ness.
IMPORTANT: Leave wiring harness side dis-
connected.
1
smr2005-058-008_a
1. Do not plug these connectors
Setmultimeterto .
Connect multimeter between YELLOW wires.
TERMINAL RESISTANCE @
20°C(69°F)
Any YELLOW wire and
engine ground
infinity (open circuit)
Read resistance.
If there is a resistance or continuity, the stator
coils and/or the wiring is grounded and needs
to be repaired or replaced.
Replug connectors properly.
Dynamic Test
AC Voltage Test
Disconnect the voltage regulator/rectifier con-
nectors.