EasyManuals Logo

Shihlin electric SE3 Series User Manual

Shihlin electric SE3 Series
374 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #211 background imageLoading...
Page #211 background image
Application parameter group 10
PARAMETER DESCRIPTION 209
Group
Parameter
Number
Name
Setting Range
Default
Page
10-42
P.702
VF separated voltage Acc
time
0~1000.0s
0.0s
226
10-43
P.703
VF separated voltage Dec
time
0~1000.0s
0.0s
226
10-44
P.704
VF separated stop
selection
0: Frequency/voltage independently decreases to 0.
0
226
1: After the voltage decreases to 0, frequency
decreases.
10-45
P.267
Regeneration avoid
function selection
0: Off.
0
227
1: Regeneration avoid function is always on.
(Automatic calculate Acc/Dec speed )
2: Regeneration avoid function is on only during
constant speed operation (Automatic calculate
Acc/Dec speed )
11: Regeneration avoid function is always on.
(Manual mode, Acc/Dec speed is set by
10-49(P.271) and 10-50(P.272))
12: Regeneration avoid function is on only during
constant speed operation (Manual mode, Acc/Dec
speed is set by 10-49(P.271) and 10-50(P.272))
10-46
P.268
Regeneration avoid action
voltage level
220V : 155~400V
380V
227
440V : 310~800V
760V
10-47
P.269
Regeneration avoid
function DC bus voltage
detection sensitivity at
deceleration
0: Prevent regeneration avoidance from failing
according to bus voltage change rate
0
227
1~5: Set the sensitivity to detect the bus voltage
change rate. Larger number, higher sensitivity.
10-48
P.270
Regeneration avoid
frequency compensation
value
0~10.00Hz: Set the limit value of regenerative avoid
frequency compensation.
6.00Hz
227
99999: Off.
10-49
P.271
Regeneration avoid
voltage gain coefficient
0~400.0%/0~40.0%
100.0%
227
10-50
P.272
Regeneration avoid
frequency gain coefficient
0~400.0%/0~40.0%
100.0%
227
10-51
P.264
Over excitation
deceleration
0: Off.
0
228
1: Over excitation deceleration is valid.
10-52
P.265
Over excitation current
level
0~200.0%
150.0%
228
10-53
P.266
Over excitation gain
1.00~1.40
1.10
228
10-54
P.362
Short-circuit brake time
when PM motor start
0~60.0s
0.0s
228

Table of Contents

Other manuals for Shihlin electric SE3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SE3 Series and is the answer not in the manual?

Shihlin electric SE3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSE3 Series
CategoryInverter
LanguageEnglish