Application parameter group 10
PARAMETER DESCRIPTION 209
VF separated voltage Acc
time
VF separated voltage Dec
time
VF separated stop
selection
0: Frequency/voltage independently decreases to 0.
1: After the voltage decreases to 0, frequency
decreases.
Regeneration avoid
function selection
1: Regeneration avoid function is always on.
(Automatic calculate Acc/Dec speed )
2: Regeneration avoid function is on only during
constant speed operation (Automatic calculate
Acc/Dec speed )
11: Regeneration avoid function is always on.
(Manual mode, Acc/Dec speed is set by
10-49(P.271) and 10-50(P.272))
12: Regeneration avoid function is on only during
constant speed operation (Manual mode, Acc/Dec
speed is set by 10-49(P.271) and 10-50(P.272))
Regeneration avoid action
voltage level
Regeneration avoid
function DC bus voltage
detection sensitivity at
deceleration
0: Prevent regeneration avoidance from failing
according to bus voltage change rate
1~5: Set the sensitivity to detect the bus voltage
change rate. Larger number, higher sensitivity.
Regeneration avoid
frequency compensation
value
0~10.00Hz: Set the limit value of regenerative avoid
frequency compensation.
Regeneration avoid
voltage gain coefficient
Regeneration avoid
frequency gain coefficient
Over excitation
deceleration
1: Over excitation deceleration is valid.
Over excitation current
level
Short-circuit brake time
when PM motor start