Setup Data 5
Background 5.1
234
5.1 Background
A short review Setup-data were introduced for CMS machines (starting with ST 711) in
1998.
Following data can be saved to the setup-file:
WMF(Fabric take-down menu)
NP (All NP values)
YD (Position of yarn carriers at the fabric selvedge)
MSEC (indirect MSEC-setting)
YLC (Yarn Length Control STIXX/ASCON)
This was the first step to write the pattern related parameters into a separate
file. The purpose is to reduce the time of setting up the machine.
Some pattern related parameters were still written in Sintral functions.
Leading to setup work when converting the pattern for other machines.
You can use the extended setup data from now on.
In order to distinguish them they will be called Setup2 and the previous data
Setup1.
The target of Setup2 Transferring a pattern from one machine to another without changing the
Sintral program.
Setup2 is extended by the following parameters:
Yarn carrier staggering (YD / YDI)
Correcting the Normal Yarn Carriers (YC / YCI)
Cycle Counters
Racking Corrections
Correction of the stitch length of the right carriage with tandem
operation (NPR)
Yarn length control at the left and right-hand side
Correction value for clamping depth (NCC)
Comments