151
4 Adjusting knitting machine
4.2 Advanced adjustments
4.2.3 Adjusting sensor mechanism *
"Sensors" window
Field Data shown
1 Stop resistance
Value range: 1-32, 1=not sensitive, 32=very sensitive
2 Carriage speed after small knots
3 Activating/deactivating of horn and selection of volume in three degrees:
0=off 1=low, 2=middle, 3=loud
Intermittent tone
Switching on/off an intermittent tone for the horn.
Interval (sec)
The time (pause) between two intervals is adjustable (max. 60
seconds).
4 If the comb take-down moves upward for fabric transfer, a light barrier
checks whether the previously produced knitted panel has completely
been ejected.
5 Monitoring of main take-down. If the fabric take-down roller has not
turned after "n" (0-100) knitting rows, a stop motion is carried out
(0=monitoring off).
6 Monitoring of main take-down. If the roller turns too quickly, a stop
motion is carried out (e.g. when the fabric is ejected). Value range: 1-32,
1=not sensitive, 32=very sensitive
7 Monitoring of auxiliary take-down. If the auxiliary take-down has not
turned after "n" (0-100) knitting rows, a stop motion is carried out
(0=monitoring off).