Maintenance of the knitting machine 6
Cleaning the knitting machine 6.2
284
6.2.11 Clean the knitting systems
1. Stop the knitting machine.
2. Move the carriage assembly into the left reversing position.
3. Set the main switch to "0" and wait until the touch screen is switched off.
4. Remove the carriage part.
5. Vacuum off the knitting systems and selection systems.
6. Clean the selector systems and pulse generators with a clean cloth.
7. Check the cams for wear and damage.
8. Apply oil to the cams with a brush.
9. Set the carriage part on the needle bed again.
10. Repeat step 4 to 9 for all carriage parts.
11. Set the main switch to "1".
The carriage position is re-referenced.
IMPORTANT
Damage to the knitting systems!
Dirt will be blown into the guides of the movable parts and the
knitting systems will be damaged if they are blown out with
compressed air.
Always vacuum off the knitting systems, never blow them
out.
IMPORTANT
Damage to the selection systems and impulse givers!
The selection systems and impulse givers will be damaged if
they are cleaned with acetone or trichlorethylene (Tri).
Clean the selector systems and pulse generators with a
clean cloth.