3 Producing with the knitting machine
3.3 Production
3.3.5 Monitoring the running time
The running times of sequence lists, sequences or orders, their individual
elements or individual patterns are recorded and displayed in the "Running
time control" window.
This adds extensive knitting process data to the commands MIN, MINSEQ
and MINSEQEL:
Display of the running time of a pattern (sequence,sequence element,
order).
The current, last, minimum, maximum and average running times are
displayed respectively.
Display of the expected remaining running time of a pattern (sequence,
sequence element, order).
Display of the number of pieces that have been knitted and are still to
be knitted.
Display of running time with or without loading and standby times.
In order to display the "Running time control" window it must
be activated in the "Knit report configuration" window.
(BootOkc --> Restart and Configuration --> Knit report
configuration --> Additional function keys)
Key Function
Call up the "Service" window
Call up "Statistics" window
Call up the "Running time control" window
Call up the "Running time data sequence" window or the "Running
time data pattern" window
Call up the "Catalog running time data" window
Returning to the previous window
Call up the "Main menu"