Repairing the knitting machine 7
Replacing parts 7.3
308
Type 2
To replace the intermediate slider, you need a small pair of pliers.
Replacing the intermediate slider
1. Push the needle and coupling part (1) upward.
2. Push the intermediate slider (2) until the lower butt bumps into the cover
rail (3).
3. Pull the upper butt of the intermediate slider out of the needle bed while
pressing the lower butt into the needle bed and under the cover rail.
4. Install the new intermediate slider in the reverse order.
5. Slide the needle and coupling part into the home position.
Valid for:
E5 │ E7 │ E8