Repairing the knitting machine 7
Replacing parts 7.3
312
Remove needle bed or
position it at an angle
1. Front needle bed: Swivel towards the front carefully and lean it against
the machine covering.
2. Rear needle bed: Remove the needle bed from the machine with two
persons.
Screwing on needle bed tight
Installing front and rear needle beds
Reassemble the needle bed in the reverse order. When doing so, make
sure that the needle bed contacts the pin (1) and the roller (2).