8 Software - Installation and basic settings
8.1 Boot process
Error diagnostics with Copy
Logfiles
If the machine computer has serious problems, e.g. it does not react to any
inputs or the program crashes any longer, the cause is very important for
Stoll. The computer saves the data up to the fault internally in so-called
Logfiles. For an exact error diagnosis, we want to ask you to save these
files and to send them to the Stoll-Helpline.
1. Tap on the key "Copy Logfiles".
A selection window for saving a file is displayed.
2. Select the saving location.
3. Confirm input.
The log files are zipped, and saved on the target medium (file
name:Log_date_time_mcnr.zip).
Restore the last version of
the Stoll operating system
1. Tap on the key "Restore Last Version".
A dialog window for confirming the restoration appears.
2. Confirm message.
The "BootOkc" window is displayed. The source (Boot Source)
"Previous Version (HD)" is automatically set.
3. When the Stoll operating system is to be installed without the final
configuration tap on the key "Installation".
- or -
When the Stoll operating system is to be installed with the final
configuration, tap on the key "Installation and Configuration".
The Stoll operating system gets installed.
The current operating system version will be overwritten!
When you restore the saved operating system version, the
current operating system version is overwritten.
Only carry out the following steps if you want to replace the
current operating system by the previous version.

Table of Contents