Error Code Error Type Error Text / Remarks
4100 WARNING
DESK, No communication to ‘Fader module at Port ‘43’ on ‘Container100’.
4101 WARNING
DESK, File ‘fader3.hex’ not found. Firmware download to ‘Fader module at Port ‘43’ on ‘Container100’
failed.
4102 WARNING
DESK, Fader calibration failed, one or more fader uncalibrated on Fader module at Port ‘43’ on
‘Container100’.
4104 WARNING
DESK, Missing Fader module at Port 12 on ‘Container100’.
4105 WARNING
DESK, Wrong module type at Port
‘12’ on ‘Container100’. A ‘Fader’ module is expected instead of a
‘Rotary’ module.
4106 WARNING
DESK, One or more faders uncalibrated on Fader module at Port ‘43’ on ‘Container100’.
4107 WARNING
DESK, Could not open port COM‘X’.
4108 WARNING DESK, Main Power Supply fail.
4109 WARNING DESK, Redundant Power Supply fail.
4110 WARNING
DESK, Could not find folder ‘Firmware’.
4200 WARNING CONFIG, AutoConfig not completed! No input modules detected. No Initial Snapshot created.
4201 WARNING CONFIG, AutoConfig not completed! No output modules detected. No Initial Snapshot created.
4202 WARNING
CONFIG, AutoConfig cannot complete to map all input signals to LogicalInputs. Increase the number of
LogicalInputs and re-run auto configuration.
4203 WARNING
CONFIG, AutoConfig cannot complete to map all output signals to LogicalOutputs. Increase the number of
LogicalOutputs and re-run AutoConfig.
4204 WARNING
CONFIG, AutoConfig detected unknown IO-Card in Slot
‘7’.
4210 INFO CONFIG, Screen Lock cannot be activated for the administrator.
4211 WARNING CONFIG, Alias is already in use! Alias will not be changed.
4212 WARNING
DESK, The Alias
‘Input 1’ appears twice in the range of LogicalInputs of Desk ‘Primary Desk’.
* 4214 WARNING
CONFIG, Not enough DSP channels.
The format of input “DVD 5.1” cannot be changed.
* 4215 WARNING
CONFIG, Insert “PCM 90” de-assigned from input “DVD 5.1”, since the format of the input has been
changed to 5.1.
4300 WARNING SYSTEM, Logon failed: Wrong user name or password.
4301 WARNING USER, User name is already in use. The user name has to be unique.
4302 WARNING
SYSTEM, No Policy defined. User ‘John’ logged in, but all access denied.
4303 WARNING
SYSTEM, One or more policies missing. User ‘John’ logged in, but access privileges may be reduced.
4400 WARNING
DESK, Mic Control Access to input
‘Mic 1’ no longer provided. Desk ‘PRI DESK’ of System ‘SR-3’ has
gained access.
4500 WARNING
CONFIG, The CODEC return line of input
‘Codec1’ is no longer connected to ‘Cent 04’ of system ‘P422’.
4600 WARNING CONFIG GUI, The item ‘LogInp1’ is already contained in the Selection! ‘LogInp1 not added.
* OnAir 3000 only

Table of Contents

Other manuals for Studer OnAir 2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer OnAir 2500 and is the answer not in the manual?

Studer OnAir 2500 Specifications

General IconGeneral
BrandStuder
ModelOnAir 2500
CategoryRecording Equipment
LanguageEnglish

Related product manuals