OnAir 2500 Digital Mixing Console
5-90 Operation
Date printed: 18.07.08
SW V3.0
OnAir 2500 Digital Mixing Console
Operation 5-91
Date printed: 18.07.08
SW V3.0
5.12.3.12 I/O Sharing
Error Code Error Type Error Text / Remarks
8500 WARNING IOSHARING, Did not find XML-file: xml\IoSharing.xml
8501 WARNING IOSHARING, Could not reset physical connection since it is still in use!
8502 WARNING IOSHARING, Could not reset logical connection since it is still in use!
8503 WARNING
IOSHARING, I/O Sharing not enabled on system ‘P422’. Missing dongle or license key. IO-Sharing will not
work properly.
8504 WARNING
IOSHARING, Audio connection could not be established, since there are too few physical connections
available. No audio on ‘left channel’ of ‘Logical Input’ ‘Label’!
8506 WARNING
IOSHARING, Could not reset NetInput since it is still in use by ‘Ext MonSource16’ on system ‘P422’.
8507 WARNING
IOSHARING, Connection to producer Core ‘System71’ lost.
8508 WARNING
IOSHARING, Conflict while system ‘P422’ is re-establishing a physical connection. The ‘left channel’ of
the local output ‘LogOut44’ will be disconnected and re-used for the physical connection to system ‘P422’!
8509 WARNING
IOSHARING, Conflict while re-establishing a physical connection to HD Link ‘35’. Physical output ‘Ext 4,
Slot 3, Line Out, Ch.33’ of system ‘P422’ is already used by a physical connection to system ‘P321’. The
physical connection could not be established!
5.12.3.13 Time Sync
Error Code Error Type Error Text / Remarks
* 9000 WARNING TIME SYNC, No communication to Time Sync Card.
* 9001 WARNING TIME SYNC, Could not open port COM‘X’
* OnAir 3000 only
5.12.3.14 Audio Clock
Error Code Error Type Error Text / Remarks
* 9100 ERROR AUDIO CLOCK, No communication to Audio Clock Card.
9101 WARNING AUDIO CLOCK, Could not open port COM1
9102 WARNING
AUDIO CLOCK, Clock reference changed to ‘WordClock’.
9103 ERROR
AUDIO CLOCK, Missing external ‘WordClock’.
9104 WARNING AUDIO CLOCK, Fileaudioclock_ext.ini not found.
* OnAir 3000 only

Table of Contents

Other manuals for Studer OnAir 2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer OnAir 2500 and is the answer not in the manual?

Studer OnAir 2500 Specifications

General IconGeneral
BrandStuder
ModelOnAir 2500
CategoryRecording Equipment
LanguageEnglish

Related product manuals