OnAir 2500/OnAir 3000 Digital Mixing Consoles
6-60 Conguration
Date printed: 22.07.08
SW V3.0
OnAir 2500/OnAir 3000 Digital Mixing Consoles
Conguration 6-61
Date printed: 22.07.08
SW V3.0
Notes: On power up, Level is initialized according to the input signal.
Time, Polarity, and Triggered Edge must not be changed while the GP
output is active.
For correct take-over after a modication, it is important to select Activate
to On, because it is automatically set to Off when a modication is made.
GPO Function Arguments Description
FaderstartWithPFL
Logical Input Fader start with ON key and fader, or PFL
FaderstartWithoutPFL
Logical Input Fader start with ON key and fader
RedLight_ONAIR
- Active if the ON AIR LED is on
RedLight_PGMA
- Active if PGM A is on air
* RedLight_PGMB
- Active if PGM B is on air
RedLight_REC
- Active if REC is on air
* RedLight_5.1A
- Active if 5.1 A is On Air
* RedLight_5.1B
- Active if 5.1 B is On Air
RedLight_CR
- Active if Control Room red light indication is on
* RedLight_ST1
- Active if Studio 1 red light indication is on
RedLight_ST2
- Active if Studio 2 red light indication is on
* RedLight_ST3
- Active if Studio 3 red light indication is on
RedLight_Input
Logical Input Active if specified strip channel is ON
MicMuteActive
Logical Input Active if mic is muted
ON
Logical Input / Strip Channel / AUX / N–X
Active if ON key is ON
TransparentOut
Device ID
Active if the value of the specified parameter is different from
zero (Function used for factory testing only!)
LinkOutput
GP Output pin Links the GP output to another GPO function
UserKey
Device ID of a user key parameter Active if the value of the specified user key parameter is true
TB
Sources: CR/*ST1/ST2/*ST3 / External
Active if the specified Talkback from Source to Destination is
active (Source = Destination is not allowed)
Destinations: All TB destinations
Locate
Logical Input Active if LOC/READY key of the logical input is on
OnMaster
Logical Input Active if channel on master is active
Next_Out
StartNextA/B_State Flashing if status = Ready, continuous if status = Next
MicGroupReady
MicGroup Active if ext. mic group key is Ready
MicGroupActive
MicGroup Active if ext. mic group key is Active or On Air
MicGroupOnAir
MicGroup Active if ext. mic group key is On Air
Setup
Setup1 / Setup 2 Active if the specified setup is active
LastSnapshot
PrimaryDesk/*SecondaryDesk/Not Spec. /
All/CR/*ST1/ST2/*ST3 / String
Active if the last loaded Global Snapshot is the one with the
name specified by “string”
OutputRoutingOut
Partial Output Routing
Active if the cross points of the specified partial output routing
are set as specified by “string”
ForwardInput
GP Input Pin
Active if the specified input pin is active
* OnAir 3000 only

Table of Contents

Other manuals for Studer OnAir 2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer OnAir 2500 and is the answer not in the manual?

Studer OnAir 2500 Specifications

General IconGeneral
BrandStuder
ModelOnAir 2500
CategoryRecording Equipment
LanguageEnglish

Related product manuals